Date Type Detail File
2021-09-09 Hardware Reason for Change
*Improve the durability and stability
*Enhance the body structure
*Circuit optimization and protection
*Optimized circuit and parts protection

Description of Engineering Change
*Remove the SD Card slot and change it to 64GB internal storage
*Move the AC power from the side to the back
*The size has been changed from 28.5 x 23.5 x 5.8 cm to 30.5 x 23.5 x 6 cm
*Weight changed from 2 kg to 3.3 kg

Effects of Change
*The shell is not compatible with the old model
*The bakelite is not compatible with the old model
*Hand pressure fixture is not compatible with the old model
*Stand alone need to reconnect with PC to replace files
*Old version of programmer will be no longer updated or fixed but replaced by a latest model version
*Size and power supply position adjustment
Engineering Change Notice _Progmaster 20210823.pdf
2016-02-01 Socket Adaptors Change Socket Supplier

SPI-100-BGA024-080060-01BM => SPI-100-BGA024-080060-001O

SPI-100-BGA024-060080-01DM02 => SPI-100-BGA024-060080-001O02